U.S. flag

An official website of the United States government

Format

Send to:

Choose Destination

ERX6191928: Illumina HiSeq 1500 paired end sequencing; RNAseq of Staphylococcus aureus wildtype and two-Cys-type TetR repressor GbaA deletion mutant under nonstress condition
2 ILLUMINA (Illumina HiSeq 1500) runs: 15.6M spots, 2.2G bases, 1Gb downloads

Design: RNAseq of Staphylococcus aureus wildtype and two-Cys-type TetR repressor GbaA deletion mutant under nonstress condition
Submitted by: Center for Biotechnology (CeBiTec), Bielefeld University, Bielefeld, Germany Institute for Biology-Microbiology, Freie Universitat Berlin, Berlin, Germany (Center for Biotechnology (CeBiTec), Bielefeld Univ)
Study: RNAseq of Staphylococcus aureus wildtype and two-Cys-type TetR repressor GbaA deletion mutant under nonstress condition
show Abstracthide Abstract
To investigate the changes in gene expression of Staphylococcus aureus COL and the gbaA deletion mutant under nonstress condition, strains were cultivated in RPMI1640 medium (Lonza) under vigorous agitation at 37°C in triplicate until cells have reached an optical density at 500?nm of 0.5. S. aureus cells were harvested and disrupted in 3 mM EDTA/ 200 mM NaCl lysis buffer with a Precellys24 Ribolyzer. RNA isolation was performed using the phenol-chloroform-isoamylalcohol approach. After precipitation with 3 M sodium acetate and isopropanol, the total RNA was washed with cold ethanol and the pellet was solved in sterile water. Initially RNA quality was checked by Trinean Xpose (Gentbrugge,Belgium) and Agilent RNA Nano 6000 kit on Agilent 2100 Bioanalyzer (Agilent Technologies, Böblingen, Germany). Samples contaminated with DNA were treated with DNase (Qiagen), cleaned as described above and rechecked by Xpose and Agilent Bioanalyzer. Finally RNA was free of DNA with an RNA Integrity Number (RIN) > 9 and rRNA Ratio [23s / 16s] > 1.5. Ribo-Zero rRNA Removal Kit (Bacteria) from Illumina (San Diego, CA, USA) was used to remove the ribosomal RNA molecules from the isolated total RNA. Removal of rRNA was checked by Agilent RNA Pico 6000 kit on Agilent 2100 Bioanalyzer (Agilent Technologies, Böblingen, Germany). RNA was free of detectable rRNA. TruSeq Stranded mRNA Library Prep Kit from Illumina (San Diego, CA, USA) was used to prepare cDNA libraries. The resulting cDNAs were sequenced paired end on an Illumina HiSeq 1500 system (San Diego, CA, USA) using 70 bp read length.
Sample: COL_DEL_gbaA_co3
SAMEA9807817 • ERS7486456 • All experiments • All runs
Library:
Name: COL_DEL_gbaA_co3_p
Instrument: Illumina HiSeq 1500
Strategy: RNA-Seq
Source: TRANSCRIPTOMIC
Selection: Inverse rRNA
Layout: PAIRED
Construction protocol: Staphylococcus aureus COL and the gbaA deletion mutant cultivation under nonstress condition was performed in RPMI1640 medium (Lonza) under vigorous agitation at 37°C in triplicate until cells have reached an optical density at 500 nm of 0.5. S. aureus cells were harvested by centrifugation and fixed in liquid nitrogen. Strain cultivation was performed in RPMI1640 medium (Lonza) under vigorous agitation at 37°C in triplicate until cells have reached an optical density at 500 nm of 0.5. S. aureus cells were harvested by centrifugation. S. aureus cells were harvested and disrupted in 3 mM EDTA/ 200 mM NaCl lysis buffer with a Precellys24 Ribolyzer. RNA isolation was performed using the phenol-chloroform-isoamylalcohol approach. After precipitation with 3 M sodium acetate and isopropanol, the total RNA was washed with cold ethanol and the pellet was solved in sterile water. Initially RNA quality was checked by Trinean Xpose (Gentbrugge,Belgium) and Agilent RNA Nano 6000 kit on Agilent 2100 Bioanalyzer (Agilent Technologies, Böblingen, Germany). Samples contaminated with DNA were treated with DNase (Qiagen), cleaned as described above and rechecked by Xpose and Agilent Bioanalyzer. RNA was free of DNA with an RNA Integrity Number (RIN) > 9 and rRNA Ratio [23s / 16s] > 1.5. Ribo-Zero rRNA Removal Kit (Bacteria) from Illumina (San Diego, CA, USA) was used to remove the ribosomal RNA molecules from the isolated total RNA. Removal of rRNA was checked by Agilent RNA Pico 6000 kit on Agilent 2100 Bioanalyzer (Agilent Technologies, Böblingen, Germany). RNA was free of detectable rRNA. TruSeq Stranded mRNA Library Prep Kit from Illumina (San Diego, CA, USA) was used to prepare cDNA libraries.
Experiment attributes:
Experimental Factor: genotype: gbaA deletion
Runs: 2 runs, 15.6M spots, 2.2G bases, 1Gb
Run# of Spots# of BasesSizePublished
ERR65658807,706,6941.1G505.1Mb2021-11-03
ERR65658817,896,3331.1G522Mb2021-11-12

ID:
17411111

Supplemental Content

Recent activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...